TOP > Power supply connection for reefer containers
冷凍コンテナの電源接続
冷凍コンテナ電源接続1
Power supply for reefer containers has the structure to switch to 200V and 400V for international use.
Three-phase 200V is preferable for domestic use.
Marine outlet equipped with the container has two plugs, and a large plug is for 200V and the other small is for 400V.
冷凍コンテナ電源接続2
Please make sure " unit switch " and " circuit breaker " of the container are " OFF " before turning on the power.
冷凍コンテナ電源接続3
Take out the plug for 200V as photos above show, and connect the electrical cables to the breaker.
☆Official license for electrical worker (Second Class ) is required in Japan for those operation.
冷凍コンテナ電源接続4
After connection of electrical cables to the breaker, turn on the switch in order below.
① Circuit breaker
② CP1 Controlling Circuit Breaker
③ Unit Switch